Answers for epa exam 7th edition. EPA 608 Practice Exam (2019 current). Fully Explained Answers. 2019-02-22

Answers for epa exam 7th edition Rating: 6,6/10 1160 reviews

How to pass the EPA 608 certification exam test

answers for epa exam 7th edition

Air in a refrigeration system will cause higher discharge pressures. The stratosphere is the Earth's security blanket. So support in anyway possible is certainly appreciated. If a strong odor is detected during the recovery process, a compressor burn-out has likely occurred. When the sight glass changes color, the system contains excessive moisture and will need to be evacuated. Considering that the actual exam has 25 questions per section.

Next

How to pass the EPA 608 certification exam test

answers for epa exam 7th edition

A system-dependent passive recovery process for small appliances captures refrigerant into a non-pressurized container. Most low-pressure recovery machines utilize a water-cooled condenser that is connected to the municipal water supply. See water vaporization chart in back of manual. The refrigerant then travels to the evaporator, 2. However, introducing liquid refrigerant into a deep vacuum will cause the refrigerant to boil and may lower temperatures enough to freeze water in the tubes.

Next

EPA TEST CERT 608 FOR REFRIGERANTS

answers for epa exam 7th edition

Small appliances are equipped with a straight piece of tubing that can be used to install a piercing type access fitting. At high temperatures, R-12 and R-22 decompose to form Hydrochloric acid, Hydrofluoric acid, and Phosgene gas. A system that uses a capillary tube or fixed bore metering device is usually equipped with an accumulator, which would be located in the suction line directly following the evaporator. These are special charcoal activated plastic bag containers. The most efficient method of leak checking a charged low-pressure refrigeration unit is to pressurize the system by the use of controlled hot water or heater blankets.

Next

How to pass the EPA 608 certification exam test

answers for epa exam 7th edition

Refrigerators built before 1950 may have used Methyl Formate, Methyl Chloride, or Sulfur Dioxide as refrigerant and should not be recovered with current recovery devices. For instance, an average 350 ton R-11 chiller at 0 psig still contains 100 lbs. After recovering refrigerant, if nitrogen is used to flush debris out of the system, the nitrogen may be vented. Section 608 of the Federal Clean Air Act requires that all persons who maintain, service, repair, or dispose of appliances that contain regulated refrigerants, be certified in proper refrigerant handling techniques as of November 14, 1994. The source of most non-condensables is air. There is some specific information you will need to know about blends. It is even bigger than the porn industry.

Next

EPA TEST CERT 608 FOR REFRIGERANTS

answers for epa exam 7th edition

Provides the fundamentals behind current energy saving equipment options, energy auditing, effects of building infrastructure on efficiency, and energy saving preventative maintenance. Education is the key if you want to earn a college degree and a secure future. Exceeding 10 psig can cause the rupture disc to fail. If you feel that your exam has had adequate time to have been mailed, received and graded, but your results are not yet posted, please contact your proctor to determine how and when your test was mailed. Even when when the text was hard to read nobody every complained so you can rest assured that you are getting a quality document. System dependent devices may only be used on appliances containing 15 lbs.

Next

How to pass the EPA 608 certification exam test

answers for epa exam 7th edition

Churches,schools,jails,goverment building,laboratories ,resturants etc are always being build and will need comfort cooling and heating and depending on the venue humidy control. The refrigerant vapor then travels to the inlet of the compressor, 4. This manual has been assembled with the most current information available at the time of this edition. The owner of this website, www. Little did we know that the use and release of these compounds into the atmosphere would have far reaching effects on our environment.

Next

EPA 608 Practice Tests

answers for epa exam 7th edition

Donations and ad revenue and the sale of different multimedia content is the only reason this site exist. Hygroscopic oil has a high affinity for water. A system that uses a thermostatic expansion valve is usually equipped with a receiver, which would be located in the liquid line directly following the condenser. When recovering refrigerant from a system that experienced a compressor burn-out, watch for signs of contamination in the oil. Long hoses will cause excessive pressure drop, increased recovery time, and have a potential for increased emissions.

Next

EPA Certification by Mainstream Engineering

answers for epa exam 7th edition

Controlled hot water can be used to pressurize a system for the purpose of opening the system for a non-major repair. Follow Us On Twitter a Our Scribd account. During evacuation of systems with large amounts of water, it may be necessary to increase pressure by introducing nitrogen to counteract freezing. You will help keep this site alive with all new stuff. It is not possible to over evacuate a system. There are two main companies that give the test, Esco, and Mainstream Engineering.

Next

EPA Cert Exam Study Manual 7th Edition

answers for epa exam 7th edition

There are two basic types of recovery devices. The technician must isolate a parallel compressor system in order to recover refrigerant. Make certain you are using the correct oil for the refrigerant. When installing an access fitting onto a sealed system, the fitting should be leak tested before proceeding with recovery. The length of the hose between the unit being recovered from and the recovery machine will greatly effect the efficiency of the recovery process.

Next